Description
GeyserWise Max Geyser Complete Kit
Control box
The control unit is the brain of the system. It performs all the programmed functions and
sends instructions to the pump and the element.
Display unit
An array of useful information can be displayed. This includes the temperature of
the water in the geyser, the temperature in the collector, whether the pump is running
or not, when the element is on, actual kW used, etc.
Water geyser sensor
The water geyser sensor measures the temperature in the geyser and acts as a
thermostat.
- Use as a geyser timer
Clear display of water temperature, time, day, heating mode and malfunction conditions. - Auto or manual heating.
- Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C.
- Four different temperature settings.
- Daily programmable timer with four time settings.
- Error conditions alert by warning code E1 to E7.
- Electronic thermostat with mechanical thermal cut-out at 90°C.
- Use as timer on a thermosyphon solar system
- Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.
- Auto or manual heating.
- Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C.
- Four different temperature settings.
- Daily programmable timer with four time settings.
- Error conditions alert by warning code E1 to E7.
- Electronic thermostat with mechanical thermal cut-out at 90°C.
- Please note the cut-out temperature for solar systems expected to
reach temperatures above this temperature. - Use as timer and dierential control on pumped solar system
- Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.
- Auto or manual heating.
- Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C.
- Four different temperature settings.
- Daily programmable timer with four time settings.
- Error conditions alert by warning code E1 to E9.
- Electronic thermostat with mechanical thermal cut-out at 90°C.
- Please note the cut-out temperature for systems expected to reach
temperatures above this temperature - Differential controller for 12V and 220 volt pumps.
Technical parameters - Operating voltage 230VAC / 50HZ.
- Main relay contact rating 30AMP (Max 4KW).
- Secondary relays pump and solenoid 5Amp.
- Operating voltage range 160V – 250V AC.
- Earth leakage protection at 25MA action time 0,1 second.
- Temperature display range 0 – 200°C (“-5” when below -5°C “EA” ).
- High temperature warning above 84°C.
- Temperature setting ranges 30 – 65°C (heating water electrically).
- Heat failure – when increase at a rate of less than 4°C per hour.
- Electronic thermostat with mechanical thermal cutout at 90°C.
- Dry heat detection – empty cylinder.
- Temperature tolerance ± 2%.
- Temperature differential setting 1°C.
- Switching differential 6°C.
- 2nd temperature probe for solar.
- Solar differential 7°C – 15°C.
- Temperature probe failure detection for both collector and tank.
- Temperature probe range for geyser is -30 to + 130°C.
- Temperature probe range for collector is -30 to + 260°C.
- Isolate both L + N when in off state.
- Collector antifreeze protection setting range 0 – 10°C.
- For 12V pump installation a 12V battery and 10W PV panel must
be added for battery backup.
Holiday mode.
GeyserWise MAX
Use for normal geyser application, solar thermosyphon
system, pumped solar system.
Display unit
An array of useful information can be
displayed. This includes the temperature of
the water in the geyser, the temperature in
the collector, whether the pump is running
or not, when the element is on, actual kW
used, etc.
Water geyser sensor
The water geyser sensor measures the
temperature in the geyser and acts as a
thermostat.
View our Range HERE